Please use this identifier to cite or link to this item: http://www.repository.rmutt.ac.th/xmlui/handle/123456789/452
Title: An Electric Generator driven by a Roof Ventilator
Authors: S. Dangeam
Keywords: Ventilator
Synchronous Generator
Hot air ventilation
Generator winding design
Issue Date: 25-May-2011
Publisher: Rajamangala University of Technology Thanyaburi
Abstract: This paper using three phase synchronous generator install to the roof ventilator by using the low flux density permanent magnet in rotational part and the three phase winding stator install at the ventilator base. When the ventilator rotate, the flux of the permanent magnet rotor part is moving across the air gap and induced the ac. voltage in the three phase stator winding. After that the ac. voltage is rectified to dc voltage and charged to the 12V 5A lead-acid battery. The results are the generator performance at the no-load speed 100 rpm, the generator voltage could be induced 52.3 V. At on-load, the generator could be supplied the load with the real power 1.15W. For the results after install the generator in the ventilator on the roof of a building to charge the 12V battery, and the minimum wind speed for enough charging to battery is at 20 rpm.
URI: http://www.repository.rmutt.ac.th/dspace/handle/123456789/452
Appears in Collections:ประชุมวิชาการ (Proceedings)

Files in This Item:
File Description SizeFormat 
ET09r.pdfAn Electric Generator driven by a Roof Ventilator995.49 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.