Please use this identifier to cite or link to this item: http://www.repository.rmutt.ac.th/xmlui/handle/123456789/380
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLiawrungrath, S.
dc.contributor.authorPurachat, P.
dc.contributor.authorOungpipat, W.
dc.contributor.authorDongduen, C.
dc.date.accessioned2012-02-28T07:08:05Z
dc.date.accessioned2020-09-24T04:56:31Z-
dc.date.available2012-02-28T07:08:05Z
dc.date.available2020-09-24T04:56:31Z-
dc.date.issued2008
dc.identifier.issn0039-9140
dc.identifier.urihttp://www.repository.rmutt.ac.th/dspace/handle/123456789/380-
dc.description.abstractA novel plant tissue-based bioelectrode obtained by incorporating sunflower (Helianthus annuus L.) leaves tissue as a source of glycolate oxidase and peroxidase into a ferrocene-mediated carbon paste electrode for the determination of glycolic acid was developed. It Was Coupled with the flow-injection (FI) system and used as the basis to develop a novel FI amperometric procedure for glycolic acid determination. The flow-injection amperometric measurements were performed by injecting aliquot of glycolic acid solution into the flowing stream of 0.05 mol L(-1) of phosphate buffer solution having pH 8.0 with a flow rate of 0.3 mL min(-1). The bioelectrode consisted of 20% (w/w) of sunflower leaves tissue and 5% (w/w) of ferrocene at 0.00 V (vs Ag/AgCl). The bioelectrode exhibited a linear response from 1.0 x 10(-6) up to 2.0 x 10(-3) mol L(-1) glycolic acid with a detection limit (S/N = 3)and a quantitation limit (S/N = 10) of 1 x 10(-6) and 3.3 x 10(-6) mol L(-1), respectively. The sampling rate of 12h(-1) and a relative standard deviation of 1.67% (n = 15) were achieved. The bioelectrode response decreased to 70% of the original value within 90 continuous injections. The proposed bioelectrode was satisfactorily applied to glycolic acid determination in human urine samples after appropriate sample pretreatment. Results obtained by the FI method were compared favorably with those obtained by HPLC. It offers advantages, which included rapidity, high activity, limited stability, ease of preparation and low cost. (C) 2008 Elsevier B.V. All rights reserved.en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectPlant tissue-baseden_US
dc.subjectBiosensorsen_US
dc.subjectGlycolic aciden_US
dc.subjectFlow injectionen_US
dc.subjectAmperometryen_US
dc.titleSunflower leaves tissue-based bioelectrode with amperometric flow-injection system for glycolic acid determination in urineen_US
dc.typeArticleen_US
Appears in Collections:บทความ (Article)

Files in This Item:
File Description SizeFormat 
Sunflower leaves tissue.pdfSunflower leaves tissue-based bioelectrode with amperometric flow-injection system for glycolic acid determination in urine82.25 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.